Sunday Poster Session
Category: Endoscopy Video Forum

Xiang Yu Gao, BS
Washington State University Elson S. Floyd School of Medicine
Spokane Valley, WA
Persistent gastrocutaneous fistula (GCF) is an uncommon adverse outcome of percutaneous endoscopic gastrostomy (PEG) tube placement. While most GCFs close spontaneously, a subset requires therapeutic interventions for closure. Conventionally, endoscopic closure with sutures, argon plasma coagulation, over-the-scope clips, or surgical closure are used for definitive therapy for persistent GCFs. We report a novel endoscopic adaptation of a laparoscopic port closure device for closure of a GCF that failed conventional endoscopic therapies.
A 52-year-old female was referred for management of a persistent gastrocutaneous fistula (GCF) causing cutaneous maceration and drainage (Figure 1). She initially had a gastrostomy with a transgastric jejunal feeding tube placed for management of medication-refractory gastroparesis. The feeding tube was terminally removed but the GCF persisted necessitating multiple attempts at endoscopic closure with varying combinations of argon plasma coagulation (APC) of the margins, endoscopic suturing, an over-the-scope clip, and a combination of all three.
Due to the persistence of the GCF despite these interventions, a novel adaptation of the laparoscopic port closure device was used for endoscopic closure. An upper endoscopy with radiofrequency ablation of the margins was performed to prepare the tract for closure.
Using the laparoscopic port closure device, an introducer needle with a suture was passed transcutaneously into the gastric lumen under endoscopic visualization (Figure 2). Using a suture passer, the end of the previously placed suture was grasped within the gastric lumen, pulled across the gastrostomy tract and then out through the skin to tie a transgastric, transcutaneous knot. The suture was secured externally using the laparotomy port closure device. This resulted in complete closure of the GCF. Water insufflation testing demonstrated no leakage from the GCF. The patient tolerated the procedure well and recovered with no complications.
This case presents a successful closure of a persistent GCF using a novel endoscopic adaptation of a readily available laparoscopic port closure device. Given the persistence of the GCF despite multiple prior endoscopic interventions, the use of the port closure device may be an acceptable alternative to surgery in a subset of patients.